Concelier Connector Reason Codes
Last updated: 2026-01-16
This reference lists deterministic reason codes emitted by stella db connectors status|list|test outputs.
| Code | Category | Meaning | Remediation |
|---|---|---|---|
| CON_RATE_001 | degraded | Upstream rate limit or throttling detected. | Reduce fetch cadence, honor Retry-After, or request higher quotas. |
| CON_UPSTREAM_002 | failed | Upstream service unreachable or returning persistent errors. | Check upstream availability, retry with backoff, or switch to mirror. |
| CON_TIMEOUT_001 | failed | Connector test exceeded timeout window. | Increase --timeout or troubleshoot network latency. |
| CON_UNKNOWN_001 | unknown | No status data reported for enabled connector. | Verify scheduler and connector logs. |
| CON_DISABLED_001 | disabled | Connector is disabled in configuration. | Enable in concelier configuration if required. |