# Trust Vector Calibration Configuration # This file controls how trust vectors are automatically adjusted based on empirical feedback # Calibration service configuration calibration: enabled: true # Calibration epoch configuration # An epoch is a period during which feedback is collected before adjustments are applied epoch: # How often to run calibration (in days) intervalDays: 30 # Minimum samples required before calibration runs minimumSamples: 100 # Maximum samples to consider per epoch (prevents over-fitting) maximumSamples: 10000 # Learning rate configuration # Controls how aggressively trust vectors are adjusted learningRate: # Base learning rate (0.0 = no change, 1.0 = full replacement) base: 0.15 # Adaptive learning based on confidence in calibration data adaptive: true # Reduce learning rate when variance is high varianceReduction: true # Maximum adjustment per epoch (safety limit) maxAdjustmentPerEpoch: 0.25 # Feedback sources # Where calibration data comes from feedbackSources: # Ground truth from reachability analysis - source: "reachability" weight: 1.0 enabled: true # Customer-reported false positives/negatives - source: "customer_feedback" weight: 0.8 enabled: true # Automated testing results - source: "integration_tests" weight: 0.7 enabled: false # Only enable if test suite is comprehensive # Provider-specific calibration settings providerCalibration: # Enable per-provider calibration (vs. global only) perProviderEnabled: true # Minimum samples needed for provider-specific calibration providerMinimumSamples: 50 # Fall back to global calibration if insufficient provider samples fallbackToGlobal: true # Calibration manifest signing manifest: # Sign calibration manifests for auditability signManifests: true # Signature algorithm signatureAlgorithm: "EdDSA" # or "RSA", "ECDSA" # Store manifests for historical analysis storeManifests: true # Retention period for calibration manifests (days) retentionDays: 365 # Rollback configuration rollback: # Enable automatic rollback if calibration degrades performance enabled: true # Threshold for automatic rollback (performance degradation %) degradationThreshold: 10 # Evaluation window for rollback decision (days) evaluationWindowDays: 7 # Alerts and notifications alerts: # Notify when calibration epoch completes onEpochComplete: true # Notify when significant adjustments are made onSignificantAdjustment: true significantAdjustmentThreshold: 0.15 # Notify when calibration fails or is rolled back onFailureOrRollback: true # Comparison engine configuration # How calibration compares expected vs. actual outcomes comparisonEngine: # Metrics to track metrics: - precision # True positives / (True positives + False positives) - recall # True positives / (True positives + False negatives) - f1Score # Harmonic mean of precision and recall - falsePositiveRate - falseNegativeRate # Weighting of metrics in optimization metricWeights: precision: 0.4 recall: 0.4 f1Score: 0.2 # Comparison granularity granularity: byProvider: true # Track performance per provider bySeverity: true # Track performance per CVE severity byStatus: true # Track performance per VEX status # Calibration storage storage: # PostgreSQL schema for calibration data schema: "excititor_calibration" # Table for calibration manifests manifestsTable: "calibration_manifests" # Table for feedback samples samplesTable: "calibration_samples" # Table for adjustment history adjustmentsTable: "trust_vector_adjustments" # Environment variable overrides # STELLAOPS_CALIBRATION_ENABLED=true # STELLAOPS_CALIBRATION_EPOCH_INTERVAL_DAYS=30 # STELLAOPS_CALIBRATION_LEARNING_RATE=0.15 # STELLAOPS_CALIBRATION_MIN_SAMPLES=100